2026.03.11 Recall: Viessmann Vitorondens 200-T / 222-F Oil Condensing Boiler

11 March 2026

The following notice has been issued by the Office for Product Safety and Standards.

Product
Viessmann Vitorondens 200-T / 222-F Oil Condensing Boiler with Vitoflame 300 Oil Blue Flame Burner

Type
Gas appliances and components - Oil Condensing Boiler

Brand
Veissmann

Models
Vitorondens 200-T / 222-F; Vitoladens 300-T (33 kW)

Country of origin
Germany

Product description
The Vitorondens 200T/222F is a residential oil condensing boiler with a Vitoflame 300 blue‑flame burner, cast‑iron primary and stainless‑steel secondary heat exchanger. It is managed by an LMO burner control and Vitotronic system.

 Oil Condensing Boiler

Hazard
The product presents a high risk of asphyxiation as testing has indicated that some 2021-2023 boilers may ignite late, causing pressure damage and possible CO leaks. This could expose people in the building to unsafe exhaust gases and potentially lead to asphyxiation.

Corrective action
Veissmann have notified end users who are affected by this issue and have warned installers of the risks.

Affected users will receive a replacement ignition module and burner control unit, and a CO detector with shut-off function or conversion of the burner to current series configuration with pressure sensor.